ESR ANALYZER Specification

  • Weight
  • Approx. 7.5 kg
  • Dimension (L*W*H)
  • 400mm x 280mm x 350mm
  • Application
  • Clinical Diagnostics, Hematology Analysis
  • Material
  • High-grade ABS Plastic, Metal Components
  • Classification
  • Automated Laboratory Instrument
  • Power
  • 50W
  • Usage
  • Measurement of Erythrocyte Sedimentation Rate in blood samples
  • Voltage
  • 220V AC, 50Hz
  • Capacity
  • Up to 40 tubes
  • Product Type
  • ESR Analyzer
  • Color
  • White / Grey
  • Operate Method
  • Fully Automated / Microprocessor Controlled
 

ESR ANALYZER Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Payment Terms
  • Cash Advance (CA), Cash in Advance (CID), Cheque, Telegraphic Transfer (T/T), Letter of Credit (L/C)
  • Sample Available
  • Yes
  • Sample Policy
  • Sample costs shipping and taxes has to be paid by the buyer
  • Packaging Details
  • carton box, export quality also available
  • Main Export Market(s)
  • Asia, Eastern Europe, Western Europe, Middle East, Africa
  • Main Domestic Market
  • All India
  • Certifications
  • ISO 9001, 14001 ,CE
 

About ESR ANALYZER

ESR ANALYZER ETA-38

Features: 

Smart Technology
  •  Modern Infra Red microtechnology.
  •  Robust performance & greater efficiency.
  •  Real time detection of specimens.
  •  Real time measurement and reporting of results.
  •  Temperature compensation.
  •  Automatic compensation referred to 18 C (Manley).
  •  Modified Westergren ESR result in m0m/hr (by interpolation).
Complete flexibility
  • Random access anlyzer.
  •  Use any open chamber to automatically measure, time and report result.
  •  Provides convenience and flexibility to run tests at anytime and in any order.
  •  No batching of sample.
  •  Each reading chamber individually timed for results.
Quality and Reliability of Results
  •  Reliability of Results.
  •  Good correlation to 1 hour modified Westergren method.
  •  Excellent reproducibility (CV of 5%).
  •  Accuracy and Consistency of Results.
Productivity Advantage
  •  Measuring time : 30 minutes.
  •  20 tests per hour.
  •  Optimization of Lab Workflow Network capability.
  •  Data Management Software (DMS**) for easy management.
  •  Compact size desktop analyzer thus minimal space required.
Advanced features
  •  Graphical printout of results, if it is connected to a
  •  Stylus Printer* (which is optional).
Safety of Handling
  •  Reduced contact with potentially infectious and hazardous blood specimen
  •  Completely Closed Analysis System (while using Vacuum ESR tube for testing) prevents the user from potentially hazardous blood specimen.
Ease of Use
  •  Easy Start up.
  •  Simply plug into an on- line UPS and start testing.
  •  No training required : No special expertise required.
  •  Fully automated.
  •  Auto start of measurement.
  •  Quick Turn-around time : Easy set up of tests.
  •  Add specimen to tube.
  •  Place tube in analyzer.
  •  Results within 30 minutes.


High-Precision ESR Measurement

Utilizing advanced infrared detection, the ESR ANALYZER ensures accurate erythrocyte sedimentation assessments. The fully automated, microprocessor-controlled system streamlines laboratory workflows by delivering consistent results with high reliability. Calibration can be performed automatically or manually, supporting quality control in clinical diagnostics.


User-Centric Features and Flexibility

The instruments LCD digital display, multi-language menu, and selectable reading times (30 or 60 minutes) provide adaptability for diverse laboratory needs. Automatic temperature control and comprehensive alarm systems for errors and test completion enhance user experience and operational safety.


Versatile Data Management

Internal memory stores up to 1000 results, while data can be exported through RS232 and USB interfaces, supporting seamless integration with laboratory information systems. This capability ensures efficient record-keeping and traceability of hematology results.

FAQs of ESR ANALYZER:


Q: How does the ESR Analyzer operate to measure erythrocyte sedimentation rate?

A: The analyzer measures ESR in whole blood samples using infrared detection, providing results after 30 or 60 minutes as selected. It automatically controls temperature and processes up to 40 Westergren tubes, ensuring accurate and standardized readings.

Q: What sample types and tubes are compatible with the ESR Analyzer?

A: The analyzer accepts whole blood samples collected in EDTA or citrate and is designed for compatibility with Westergren tubes, ensuring it meets the most common laboratory protocols for ESR testing.

Q: When should calibration of the ESR Analyzer be performed?

A: Calibration can be conducted either automatically or manually as required by laboratory standards. Regular calibration is recommended to maintain optimal accuracy, especially following maintenance or relocation of the instrument.

Q: Where can the ESR Analyzer be used within a clinical or laboratory environment?

A: This instrument is suitable for use in clinical diagnostic laboratories, hematology departments, or any healthcare facility requiring routine ESR measurement. Its compact build and reliable performance make it ideal for centralized and decentralized lab settings.

Q: What is the process for exporting data from the analyzer?

A: Results can be exported through the RS232 interface or via USB. The internal storage accommodates up to 1000 results, enabling efficient data management and connectivity with laboratory information systems.

Q: How do the alarm and temperature control systems benefit laboratory workflow?

A: The automatic temperature control maintains optimal test conditions, while error and completion alarms notify users of any issues or test completion, thus improving workflow efficiency and laboratory safety.

Q: What are the key benefits of using this fully automated ESR Analyzer?

A: Key benefits include high accuracy (1 mm/hr), efficient operation with up to 40 tubes, versatile data management options, user-friendly interface with multi-language support, and robust construction, making it a reliable choice for high-throughput laboratories.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Analytical Instruments Category

Digital Salinity Meter

Digital Salinity Meter

Price 10.0 INR / Piece

Minimum Order Quantity : 1 Piece

Dimension (L*W*H) : 210 mm x 185 mm x 75 mm

Power : AC Mains or Battery operated

Classification : Laboratory & Field Instrument

Weight : 1 kg (approx.)

Microprocessor Water & Soil Analysis Kit

Microprocessor Water & Soil Analysis Kit

Price 100.0 INR / Piece

Minimum Order Quantity : 1 Piece

Dimension (L*W*H) : 320 x 220 x 100 mm

Power : Main Power Supply

Classification : Analytical Instrument

Weight : 4.5 kg

Digital Spectrophotometer

Digital Spectrophotometer

Price 100.0 INR / Piece

Minimum Order Quantity : 1 Piece

Dimension (L*W*H) : 320 mm x 220 mm x 130 mm

Power : 12 W

Classification : Analytical Laboratory Instrument

Weight : 4.5 kg

WATER SOIL ANALYSIS

WATER SOIL ANALYSIS

Price 100.0 INR / Piece

Minimum Order Quantity : 1 Piece

Dimension (L*W*H) : 28 cm x 19 cm x 13 cm

Power : Electric

Classification : Soil & Water Testing Equipment

Weight : 2.8 kg



"We deal all over World but our main domestic market is South India"
Back to top