EDUTEK INSTRUMENTATION
GST : 06AEWPJ6896D1ZU

call images

Call us

07313726362

Laminar Air Flow Table
Laminar Air Flow Table

Laminar Air Flow Table

Laminar Air Flow Table Specification

  • Frequency
  • 50 Hz
  • Measurement Range
  • 0.3 micron particle filtration
  • Core Components
  • HEPA Filter, Blower Fan, UV Lamp, Fluorescent Lamp
  • Feature
  • 99.97% HEPA air filtration, low noise operation, UV lamp for sterilization, sturdy construction
  • Automation Grade
  • Manual / Semi-Automatic
  • Model No
  • As per series/model offered
  • Voltage
  • 220-240 V AC
  • Accuracy
  • Filtration up to 0.3 micron
  • Capacity
  • As per requirement (commonly available in 3ft, 4ft, and 6ft)
  • Power Source
  • Electric
  • Temperature Range
  • Ambient
  • Equipment Materials
  • Stainless Steel (SS 304/316), Mild Steel with powder coating
  • Type
  • Horizontal / Vertical Laminar Air Flow
  • Usage
  • Laboratory, Pharmaceutical, Research, Microbiological Applications
  • Display Type
  • Analog / Digital (varies by model)
  • Dimension (L*W*H)
  • 1200 x 600 x 600 mm (customized sizes also available)
  • Weight
  • Approx. 80-110 kg (depending on size)
 

Laminar Air Flow Table Trade Information

  • Payment Terms
  • Cash Against Delivery (CAD), Cash on Delivery (COD), Cash Advance (CA), Delivery Point (DP), Letter of Credit (L/C), Letter of Credit at Sight (Sight L/C), Telegraphic Transfer (T/T), Days after Acceptance (DA), Cash in Advance (CID), Cheque
  • Delivery Time
  • 2 Week
  • Sample Available
  • Yes
  • Sample Policy
  • If order is confirmed we will reimburse the sample cost
  • Main Export Market(s)
  • Australia, North America, Eastern Europe, Middle East, South America, Western Europe, Central America, Asia, Africa
  • Main Domestic Market
  • South India, North India, West India, Assam, Arunachal Pradesh, Bihar, Chandigarh, Delhi, Gujarat, Goa, Haryana, Jammu and Kashmir, Jharkhand, Karnataka, Madhya Pradesh, Maharashtra, Mizoram, Meghalaya, Manipur, Punjab, Rajasthan, Sikkim, Tamil Nadu, Telangana, Tripura, Nagaland, Uttar Pradesh, Himachal Pradesh, Andaman and Nicobar Islands, Pondicherry, Daman and Diu, Uttarakhand, Dadra and Nagar Haveli, Lakshadweep, East India, Andhra Pradesh, Kerala, Central India, Odisha, Chhattisgarh, All India
  • Certifications
  • AS ISO 9001:2008, ISO 14001:2004 and OHSAS 18001:2007 CO.
 

About Laminar Air Flow Table

LAMINAR FLOW TABLE

Edutek are manufacturer and exporter of Laminar Flow Table for Engineering college Student.
  •  Designed to simulate ideal fluid flow and give clear visualization of the flow patterns created using water as the working fluid.
  • This enables a comprehensive investigation into the principles of potential flow and allows modelling of appropriate physical systems.
  • Floor standing apparatus demonstrates ideal flow, and Hele Shaw principles and is able to accept student made models.
  • Working section and end tanks made of glass reinforced plastic.
  • Working section dimensions 606mm x 892mm. Actual viewing area 495mm x 755mm.
  •  Lower glass plate incorporates 8 sinks/sources in cruciform pattern and viewing graticule.
  •  A system of pipes, valves and manifolds enables any configuration of sinks and sources to be used.
  •  Includes dye injection system and adjustable knife edge weir for rapid, accurate adjustment of table flow.
  • Comprehensive instruction manual with illustrations.



Advanced Dual-Stage Air Filtration

Equipped with both a pre-filter and HEPA filter, the Laminar Air Flow Table removes 99.97% of particulates down to 0.3 micron. This ensures exceptional air purity, crucial for sensitive laboratory and industrial environments, while the pressure gauge monitors HEPA filter integrity for safe operation.


UV Sterilization for Maximum Safety

Built-in UV germicidal lamps provide an additional layer of sterilization, minimizing risks of microbial contamination on the work surface. This feature is particularly valuable for microbiological and pharmaceutical applications where maintaining aseptic conditions is required.


Customizable and Durable Design

Manufactured using Grade SS 304/316 stainless steel and powder-coated mild steel, the table offers superior resistance to corrosion and wear. Sizes and display types are customizable, and optional accessories like magnetic gas taps and differential pressure gauges are available to suit varying operational needs.

FAQs of Laminar Air Flow Table:


Q: How does the Laminar Air Flow Table ensure a sterile work environment?

A: The table uses a dual filtration system comprised of a pre-filter and a HEPA filter, which captures 99.97% of particles down to 0.3 micron. Combined with controlled horizontal or vertical laminar airflow, clear acrylic side panels, and a built-in UV germicidal lamp for surface sterilization, it consistently maintains a contamination-free workspace.

Q: What are the benefits of using a Laminar Air Flow Table in laboratory and pharmaceutical settings?

A: The primary benefits include reliable particulate filtration for product and personnel protection, minimized noise (<65 dB) for comfortable working conditions, and effective sterilization via the UV germicidal lamp. Its robust construction and customizable options further ensure suitability across varied disciplines and environments.

Q: When should the HEPA filter be monitored or replaced?

A: HEPA filter status should be regularly monitored using the included pressure gauge. An increase in pressure differential indicates filter clogging, suggesting it is time for cleaning or replacement. Follow the manufacturers recommendations for maintenance intervals, or replace the filter immediately if airflow decreases or contamination is observed.

Q: Where can the Laminar Air Flow Table be installed?

A: This table is suitable for laboratories, pharmaceutical production facilities, research centers, and microbiology rooms. Its adaptable design and available custom sizes allow installation in diverse workspaces, ensuring compatibility with existing infrastructure.

Q: What optional accessories are available for this Laminar Air Flow Table?

A: Optional accessories include magnetic gas taps, extra electrical sockets, and a differential pressure gauge. These additions enhance utility and operational convenience, allowing the equipment to be tailored precisely to user requirements.

Q: How is sterilization achieved on the work surface of the table?

A: Sterilization is accomplished via a built-in UV germicidal lamp. This lamp emits ultraviolet light to eliminate microbes and maintain an aseptic environment, which is essential for microbiological and pharmaceutical operations.

Q: What is the process for maintaining and cleaning the Laminar Air Flow Table?

A: Routine maintenance involves wiping down the stainless steel work surface, replacing filters as indicated by the pressure gauge, and periodically checking the functionality of the UV lamp. Always follow safety protocols and manufacturer guidelines for cleaning and servicing to ensure optimal performance and longevity.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Fluid Mechanics Lab Equipment Category

Air Flow Studies Apparatus

Air Flow Studies Apparatus

Price 100.0 INR / Unit

Minimum Order Quantity : 1 Unit

Usage : Industrial

Weight : Approx. 3540 kg

Accuracy : 1% for Air Flow Measurement

Feature : Highly Efficient

Compressible Flow Banch

Compressible Flow Banch

Usage : Educational/Research Laboratory for Study of Compressible Flow Phenomena

Weight : Approx 65 Kg

Accuracy : 1% F.S. (Full Scale)

Feature : Durable Structure, Easy Visualization, Accurate Instrumentation

CENTRIFUGAL BLOWER TEST RIG

CENTRIFUGAL BLOWER TEST RIG

Price 500.0 INR / Piece

Minimum Order Quantity : 1 Piece

Usage : Fluid Mechanics Lab Equipment

JET PUMP TEST RIG

JET PUMP TEST RIG

Price 500.0 INR / Piece

Minimum Order Quantity : 1 Piece

Usage : Fluid Mechanics Lab Equipment



"We deal all over World but our main domestic market is South India"
Back to top