About Conductivity/Ec Meter
CONDUCTIVITY/EC METER
- Type Bench Top,
- Digital Display LCD
Measuring Range
- Conductivity: 00.0 ~199.9 mS/cm 0.0 ~199.9 ÎS/cm
- Temperature Range Ambient to 100 ÂC
Accuracy
- Â 1 % of reading
- Temperature compensation Automatic, 0 ~50 ÂC
- Electrical 9 V batteries and AC adopter 230 VAC, 50 Hz
- Spares Calibration standard 500ml,
- Electrode 01 No
Accessories:
- With EC & Temperature probe and
- Other accessories.
- Literature
- Operational manual in English
Precision and Versatility for Water AnalysisEngineered for accuracy, this meter supports both laboratory and on-site measurements, suiting a range of water quality applications. Its platinum/silver electrode ensures stable readings while single or multi-point calibration offers flexibility for diverse sample types. Auto temperature compensation guarantees precise results even in changing environments.
User-Friendly Features in a Portable DesignWith its lightweight, ergonomic construction and intuitive keypad controls, this meter provides convenience during prolonged use. The clear LCD display, data hold, and auto-off functions add to its practicality, while robust ABS casing ensures durability under regular operation in the field.
Reliable Performance and ComplianceDesigned to meet international standards, this instrument comes CE marked and boasts a high input impedance (>1 M) for robust measurement integrity. The selectable TDS conversion and salinity range up to 1999 ppm make it suitable for various analytical requirements. Power flexibility and long battery life support continuous, dependable operation.
FAQs of Conductivity/Ec Meter:
Q: How do I calibrate the meter, and how often should it be done?
A: The meter supports both single and multi-point calibration, ensuring accuracy across its measurement range. Calibration is performed using standard conductivity solutions through the keypad controls. It is recommended to calibrate the meter before each series of new measurements or whenever changing measurement solutions for optimal precision.
Q: What types of applications can this conductivity/EC meter be used for?
A: This portable meter is suitable for water quality testing in laboratories, industrial settings, field research, and environmental monitoring. Its design is ideal for analyzing drinking water, wastewater, aquaculture, and other water samples requiring precise conductivity or TDS assessments.
Q: When should I use the data hold function?
A: The data hold function is useful when you need to freeze the current reading on the display, allowing for easy recording and reference. This is particularly helpful during fieldwork or when immediate documentation of measurements is required.
Q: Where can I use this instrument safely, considering its operating conditions?
A: The device is recommended for use within the temperature range of 050C and up to a temperature resistance of 70C. Its robust ABS body and battery/adapter operation make it suitable for both indoor laboratory environments and outdoor field sites.
Q: What benefits does the platinum/silver electrode cell provide?
A: The platinum/silver electrode ensures high conductivity measurement precision and long-term durability, delivering stable results with low maintenance requirements. It also allows for more reliable calibration and consistency across varied sample types.
Q: How does the selectable TDS conversion factor enhance measurement flexibility?
A: By enabling users to select a TDS conversion factor between 0.5 and 1.0, the meter accommodates different water sample characteristics, providing tailored readings to match the specific application or industry standard in use.