EDUTEK INSTRUMENTATION
GST : 06AEWPJ6896D1ZU

call images

Call us

07313726362

Mobile Phase Filtration Assembly With Buckner Funnel
Mobile Phase Filtration Assembly With Buckner Funnel
Mobile Phase Filtration Assembly With Buckner Funnel
Mobile Phase Filtration Assembly With Buckner Funnel
Mobile Phase Filtration Assembly With Buckner Funnel
Mobile Phase Filtration Assembly With Buckner Funnel
Mobile Phase Filtration Assembly With Buckner Funnel
Mobile Phase Filtration Assembly With Buckner Funnel
Mobile Phase Filtration Assembly With Buckner Funnel
Mobile Phase Filtration Assembly With Buckner Funnel
Mobile Phase Filtration Assembly With Buckner Funnel
Mobile Phase Filtration Assembly With Buckner Funnel

Mobile Phase Filtration Assembly With Buckner Funnel

Price 1300.0 INR/ Piece

MOQ : 1 Piece

Mobile Phase Filtration Assembly With Buckner Funnel Specification

  • Features
  • Chemically Resistant, Easy to Clean, Leak-proof Seal, Autoclavable
  • Control Type
  • Manual
  • Accuracy
  • Fine Filtration with High Reproducibility
  • Speed Range
  • Manual Operation
  • Glass Type
  • High-quality Borosilicate Glass
  • Temperature Resistance
  • Up to 180C
  • Shape
  • Cylindrical Funnel with Conical Flask
  • Type
  • Mobile Phase Filtration Assembly with Buckner Funnel
  • Dimension (L*W*H)
  • Standard Laboratory Sizes
  • Equipment Type
  • Filtration Assembly
  • Equipment Materials
  • Borosilicate Glass, Stainless Steel, Silicone
  • Material
  • Borosilicate Glass (Funnel, Flask); Stainless Steel (Holder, Clamp); Silicone (Seal)
  • Application
  • HPLC Mobile Phase Filtration, Laboratory Filtration, Analytical Chemistry, Sample Preparation
  • Capacity (Ltr)
  • 1 Litre (standard flask), other capacities available
 

Mobile Phase Filtration Assembly With Buckner Funnel Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Payment Terms
  • Cash Advance (CA), Cash in Advance (CID), Cheque, Telegraphic Transfer (T/T), Letter of Credit (L/C)
  • Sample Available
  • Yes
  • Sample Policy
  • Sample costs shipping and taxes has to be paid by the buyer
  • Packaging Details
  • carton box, export quality also available
  • Main Export Market(s)
  • Asia, Eastern Europe, Western Europe, Middle East, Africa
  • Main Domestic Market
  • All India
  • Certifications
  • ISO 9001, 14001 ,CE
 

About Mobile Phase Filtration Assembly With Buckner Funnel

MOBILE PHASE FILTRATION ASSEMBLY
  • Capacity 1 liter
  • Used for filtration of mobile phase.
  • And solvents for HPLC
  • Complete with fittings,
  • 1 ltr. Buckner flask ,
  • Buckner funnel
  • Vacuum pump
  • Operating at 220-230 VAC , 50 Hz.


Advanced Filtration Reliability

Utilizing a perforated Buckner funnel and premium stainless steel filter support, this filtration assembly delivers consistent and reproducible results for laboratory-grade applications. The secure silicone seal and sturdy spring clamp guarantee a leak-proof operation, making it a reliable choice for demanding filtration tasks, such as HPLC mobile phase preparation and general laboratory filtration.


Exceptional Chemical and Thermal Resistance

Engineered with borosilicate glass and stainless steel, every component offers resistance to a wide spectrum of chemicals. This filtration assembly tolerates temperatures up to 180C, ensuring safety and stability during autoclaving or while handling a range of solvents and solutions.


User-Friendly and Versatile Design

Designed for practicality, the side-arm vacuum connection supports standard 8 mm tubing, while the assembly accommodates various filter paper sizes and flask capacities. The manual operation allows complete control, and all glass parts can be efficiently sterilized by autoclaving, making maintenance straightforward.

FAQs of Mobile Phase Filtration Assembly With Buckner Funnel:


Q: How do I assemble and use the Mobile Phase Filtration Assembly with Buckner Funnel?

A: Begin by placing the filter support (either stainless steel mesh or sintered disc) in the Buckner funnel, then position the filter paper (90 mm or other compatible size) on top. Fit the silicone gasket around the funnel and secure it to the conical flask with the stainless steel spring clamp. Connect the side-arm to a vacuum pump using 8 mm tubing, add your solution, and apply vacuum to start filtration.

Q: What are the main benefits of this filtration assembly for HPLC mobile phase preparation?

A: This assembly ensures fine particulate removal with high reproducibility and resistance to chemical contamination, resulting in clean, reliable mobile phases for HPLC. Its chemically resistant materials and leak-proof design enhance precision while supporting a wide range of solvents and strong cleaning protocols, including autoclaving.

Q: When should I utilize the stainless steel mesh versus the sintered disc as a filter support?

A: Choose the stainless steel mesh when filtering larger volumes or where faster flow rates are desired. Use the sintered disc for finer filtration and when maximum retention of small particulates is crucial, ensuring optimal results according to your samples requirements.

Q: Where can I use this filtration assembly within the laboratory?

A: The assembly is well-suited for analytical chemistry, sample preparation, and routine filtration of solvents or aqueous solutions in any standard laboratory environment, particularly where HPLC, mobile phase, or precise particulate removal is needed.

Q: What process should I follow to clean and sterilize the glass components?

A: After use, disassemble the filtration parts. Wash all glass components with suitable detergents, rinse thoroughly, and sterilize by autoclaving at temperatures up to 180C as needed. Ensure all silicone and stainless steel parts are also properly cleaned according to laboratory protocols.

Q: Is the assembly compatible with all vacuum pumps and tubing?

A: This unit features a side-arm vacuum connection tailored for 8 mm tubing, making it compatible with most laboratory vacuum pumps and standard tubing sizes. Ensure you use tubing with the correct internal diameter to maintain a leak-proof vacuum seal.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Laboratory Research Equipments Category

Hot Air Oven

Hot Air Oven

Price 1800.0 INR / Piece

Minimum Order Quantity : 1 Piece

Features : Double wall construction, uniform temperature distribution, overtemperature protection, glass window for observation, adjustable shelves, easy to clean interior

Application : Sterilization, drying, baking, curing in laboratory settings

Accuracy : 1C

Compound Microscope With Camera

Compound Microscope With Camera

Price 2100.0 INR / Piece

Minimum Order Quantity : 1 Piece

Features : Builtin camera, High magnification, Durable build, Adjustable illumination, Mechanical stage

Application : Laboratory, Research, Education

Accuracy : Highresolution imaging

Water Distillation

Water Distillation

Price 4500.0 INR / Piece

Minimum Order Quantity : 1 Piece

Features : highly efficient

Application : laboratory research equipment

Accuracy : 100 %

Warranty : 1 year

Karl Fischer Titrator Automatic

Karl Fischer Titrator Automatic

Price 7100.0 INR / Piece

Minimum Order Quantity : 1 Piece

Features : highly efficient

Application : laboratory research equipment

Accuracy : 100 %

Warranty : 1 year



"We deal all over World but our main domestic market is South India"
Back to top