CLEAVELAND FLASH POINT & FIRE POINT APPARATUS :
- Used for determining the flash and fire point of petroleum products.
- It consists of a brass cup mounted on an electric heater.
- With temperature controller. Conforming with the CE European directive.
- Supplied complete with double line-fuse.
- Hot plate control system and thermometer -6 +400°C.
- Power: 600 W.
- Weight approx.: 5 kg.
Accessories:
- Spare cup,
- Thermometer -6 +400°C,
- Gas cylinder with fitted pipe.
Reliable Flash and Fire Point DeterminationEngineered for laboratories and the petroleum industry, this apparatus ensures accurate detection of flash and fire points according to IS:1448(P-69), ASTM D92, and ISO 2592 standards. Its electric heating mechanism with a precision energy regulator makes temperature control straightforward, while the robust design guarantees longevity and safety.
Safety and User-Friendly FeaturesOperator safety is paramount, highlighted by an asbestos-insulated base and a comprehensive safety shield. The manual ignition test flame and hand-operated controls make the device user-friendly while enabling precise, repeatable testing procedures. The polished brass and GI construction enhance durability, ensuring long-term usage.
FAQs of Cleveland Flash & Fire Point Apparatus:
Q: How does the Cleveland Open Cup Apparatus determine flash and fire points?
A: The apparatus uses the open-cup method, where a petroleum sample is heated in an open brass crucible. A test flame is passed over the sample as it is gradually heated, and the temperatures at which a flash and subsequent sustained fire occur are recorded, indicating the flash and fire points.
Q: What safety features are included to protect the operator during testing?
A: This equipment is built with a heavy base for stability, an asbestos insulation sheet below the heating plate to reduce heat transfer, and a safety shield surrounding the test area. These features collectively ensure operator safety throughout the testing process.
Q: When should I use this apparatus for flash and fire point testing?
A: This apparatus is ideal when compliance with standards such as IS:1448(P-69), ASTM D92, or ISO 2592 is required. It is best suited for laboratories and quality control departments testing petroleum products to ensure safety and quality regulations are met.
Q: Where is the Cleveland Flash & Fire Point Apparatus manufactured and supplied from?
A: The apparatus is manufactured, exported, and supplied from India, catering to the needs of laboratories and industries worldwide that require accurate determination of flash and fire points in petroleum products.
Q: What is the process for operating the apparatus?
A: Fill the brass crucible with up to 70 ml of the test sample, set the thermometer, and gradually heat the sample using the electric heating system with the energy regulator. Manually pass the test flame over the surface at specified intervals, observing and noting the flash and fire point temperatures as required by testing standards.
Q: What are the main benefits of using this apparatus?
A: Benefits include high accuracy conforming to international standards, low power consumption, operator safety features, and robust construction. Its manual controls and clear readings make it suitable for routine testing in professional laboratory environments.
Q: Is the apparatus suitable for all petroleum products?
A: Yes, the Cleveland Open Cup Apparatus is designed for the flash and fire point determination of various petroleum products, following recognized international testing standards, making it versatile for different samples within standard laboratory practices.