EDUTEK INSTRUMENTATION
GST : 06AEWPJ6896D1ZU

call images

Call us

07313726362

Bio Medical Waste Incinerator for Hospital Waste
Bio Medical Waste Incinerator for Hospital Waste
Bio Medical Waste Incinerator for Hospital Waste
Bio Medical Waste Incinerator for Hospital Waste
Bio Medical Waste Incinerator for Hospital Waste
Bio Medical Waste Incinerator for Hospital Waste
Bio Medical Waste Incinerator for Hospital Waste
Bio Medical Waste Incinerator for Hospital Waste
Bio Medical Waste Incinerator for Hospital Waste
Bio Medical Waste Incinerator for Hospital Waste
Bio Medical Waste Incinerator for Hospital Waste
Bio Medical Waste Incinerator for Hospital Waste

Bio Medical Waste Incinerator for Hospital Waste

Price 100000.0 INR/ Piece

MOQ : 1 Piece

Bio Medical Waste Incinerator for Hospital Waste Specification

  • Voltage
  • 220V / 440V Volt (v)
  • Capacity
  • 50 to 200 Kg/Batch Kg
  • Model No
  • Accuracy
  • 100 % %
  • Measurement Range
  • Depends on Batch Capacity
  • Core Components
  • Combustion Chamber, Auto Ignition Burner, Chimney, Control Panel
  • Power Source
  • Electric / Diesel
  • Automation Grade
  • Semi-Automatic / Automatic
  • Temperature Range
  • 800 C to 1200 C Celsius (oC)
  • Feature
  • Highly Efficient
  • Frequency
  • 50 Hz Hertz (HZ)
  • Equipment Materials
  • Mild Steel Body with Stainless Steel Internal Chamber
  • Type
  • Bio Medical Waste Incinerator
  • Usage
  • Laboratory
  • Display Type
  • Digital
  • Dimension (L*W*H)
  • 2000 x 1200 x 1700 mm approx. Millimeter (mm)
  • Weight
  • 600 to 2000 Kg Kilograms (kg)
 
 

About Bio Medical Waste Incinerator for Hospital Waste

Bio Medical Waste Incinerator for Hospital Waste

Following are the Bio Medical Waste Incinerator for Hospital Waste
offered by us:
  • Bio Medical Waste Incinerator.
  • Electronic Bio Waste Medical Incinerator.
  • Bio Waste Oil Fired Medical Incinerator.
Features Bio Medical Waste Incinerator
  •  Robust construction.
  •  Virtually smoke and smell free with secondary burners.
  •  High temperature refractory lining.
  •  Quick heat up time and lesser operational time.
  •  Easy installation.
  •  Trouble free operation and maintenance.
  •  Designed to meet standards of central Pollution Control Board.
  • Available in oil, gas or electrically fueled
 Our incinerators have following components:
  •  Primary Chamber, Secondary Chamber, Air Blowers, Burners or electric heating elements.
  •  Feeding Door, Ash collection pit with ash tray (optional), Chimney
 Construction without scrubber:
  •  Chamber in incinerators is built as per guidelines of CPCB.
  •  The body is made of steel and lined with high temperature Refractory that make our Incinerators robust and trouble free for longer life.
  •  The construction is modular and individual components are easily assembled at site.
Applications  Hospital Medical Waste Incinerator :
  •  Medical colleges Catering wastes Resorts/Hotels Poultry.
  •  Hospitals.
  •  Nursing homes Institutions.
  •  Industrial wastes Camp wastes Municipal wastes Malls/Shopping centers.
  • Animal farms like sheep kennels.
Specifications of Incinerator :
  •  Temperatures: 1000 C.
  •  Material: Stainless steel.
  •  Burn rate: 18 to 20 kg/hr.


Advanced Waste Management Technology

The  incinerator incorporates modern engineering, featuring an automatic burner, both oil and LPG compatibility, and a microprocessor-based digital control panel for precise operation. Double-scrubbing treats flue gases, significantly reducing emissions. The fast, efficient process ensures safe disposal, with an ash residue of just 3% of the input waste, upholding environmental compliance.


Safety and User-Friendly Operation

Designed with stringent hospital protocols in mind, the incinerator includes essential safety systems such as emergency shutdown and overheat protection. Clear digital displays inform the operator at every stage, and both manual and pneumatic doors suit various workflow designs. Full on-site installation and operator training are standard, ensuring immediate, informed usage.


Durability and Flexibility in Application

With a rugged mild steel body and stainless steel internal chamber, the  resists harsh operational conditions and supports repeated use. Suitable for laboratories and hospitals, this incinerator adapts to semi-automatic or fully automatic operations, and handles batch capacities from 50 to 200 kg. Flexible fuel and power options enable seamless integration into diverse facility infrastructures.

FAQs of Bio Medical Waste Incinerator for Hospital Waste:


Q: How does the double scrubbing system benefit flue gas treatment in this incinerator?

A: The double scrubbing system efficiently treats flue gases by removing harmful particulates and neutralizing acidic gases, resulting in cleaner emissions and compliance with environmental standards. This advanced process helps protect hospital environments and the surrounding community.

Q: What procedures are followed during the on-site installation and training for the incinerator?

A: Qualified technicians perform installation at your facility, ensuring correct setup of the combustion chamber, burner, control panel, and chimney. Comprehensive user training is provided, covering safe operation, routine maintenance, emergency protocols, and optimal usage of control features.

Q: Where can this incinerator be installed and what are its space requirements?

A: The  designed for installation at hospitals, laboratories, and healthcare facilities. It requires a dedicated space measuring approximately 2000 x 1200 x 1700 mm for the main unit, plus sufficient clearance for the chimney height (710 meters) and operational access.

Q: What safety features are integrated into 

A: The incinerator is equipped with emergency shutdown, overheat protection, and user-configurable alarms, ensuring safe operation. These features minimize operational risks and protect both users and facility infrastructure during routine or emergency situations.

Q: When should ash residue be removed and what is its expected quantity?

A: Ash residue should be cleared after each incineration batch. The advanced design limits ash residue to a maximum of 3% of the input waste, enabling easier ash handling and disposal while optimizing chamber cleaning schedules.

Q: What are the main benefits of using a microprocessor-based digital control panel in this incinerator?

A: A microprocessor-based control panel ensures accurate temperature regulation, real-time process monitoring, and automated burner control. This promotes operational consistency, improves batch processing efficiency, and simplifies troubleshooting for users.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Incinerators Category

Bottle Crushing Machine

Bottle Crushing Machine

Price 100000.0 INR / Piece

Minimum Order Quantity : 1 Piece

Weight : 85 kg Kilograms (kg)

Usage : Pet Bottle Crushing

Frequency : 50 Hz Hertz (HZ)

Feature : Low Noise Operation, High Crushing Efficiency

Small Animal Incinerator

Small Animal Incinerator

Price 1000000.0 INR / Piece

Minimum Order Quantity : 1 Piece

Weight : Approx. 350 Kg Kilograms (kg)

Usage : Laboratory

Frequency : 50 Hz Hertz (HZ)

Feature : Highly Efficient

Large Animal Incinerator

Large Animal Incinerator

Price 1000000.0 INR / Piece

Minimum Order Quantity : 1 Piece

Weight : Approximately 1500 kg Kilograms (kg)

Usage : Laboratory

Frequency : 50/60 Hz Hertz (HZ)

Feature : Highly Efficient

Bio Waste Medical Incinerator

Bio Waste Medical Incinerator

Price 100000.0 INR / Piece

Minimum Order Quantity : 1 Piece

Weight : 600 Kg Kilograms (kg)

Usage : Laboratory

Frequency : 50 Hz Hertz (HZ)

Feature : Highly Efficient



"We deal all over World but our main domestic market is South India"
Back to top