About Autoclave Horizontal
Autoclave Horizontal
ETS-50A: A versatile electrically heated sterilizer under saturated steam of adjustable pressure of 10 to 20 psi. Double walled construction with boiler made of stainless steel, outer shell made of stainless steel sheet. The lid is made of stainless steel or gun-metal plate, tightening all round with wing nuts. Gasket made of molded joint-less Neoprene rubber. Equipped with water level arrangement, pressure gauge, air/steam release cock, spring loaded safety valve adjustable to any selected point from 10 psi to 20 psi, accuracy ± 3 psi and drain, cord-plug etc.; to work on 220V AC 50Hz single phase. Autoclave vertical but in horizontal position and without steam jacket.
| Dia x Depth | Load |
|
| 400 x 600mm | 5 KW |
|
| 500 x 900mm | 8 KW |
|
| 550 x 750mm | 8 KW |
|
| 400 x 1100mm | 10 KW |
|
| 500 x 1200mm | 10 KW |
|
|
|
|
Optional Accessories
- Digital microprocessor temperature controller
- Automatic low water level cut-off device
- Pressure control switch
Efficient Sterilization for Research and Clinical LabsWith adjustable pressure from 10 to 20 psi, this horizontal autoclave ensures reliable and thorough sterilization of laboratory instruments, glassware, and textiles. Its electrically heated system utilizes saturated steam to decontaminate items effectively, providing peace of mind for lab professionals concerned with safety and infection control.
Durable Stainless Steel ConstructionConstructed using double-walled stainless steel for both the boiler and outer shell, the autoclave offers lasting resistance to corrosion and thermal stress. The choice of materials extends the lifespan of the equipment and maintains a sterile environment, meeting rigorous laboratory standards.
FAQs of Autoclave Horizontal:
Q: How does the horizontal autoclave sterilize laboratory equipment?
A: The autoclave uses saturated steam under adjustable pressure ranging from 10 to 20 psi to sterilize lab items. The double-walled stainless steel construction maintains consistent temperature and pressure, ensuring effective elimination of contaminants.
Q: What safety features does this autoclave have to ensure secure operation?
A: The autoclave is equipped with a spring-loaded safety valve adjustable between 10 to 20 psi, a pressure gauge, air/steam release cock, and molded joint-less neoprene gasket to prevent leaks and maintain airtight sealing during the sterilization cycle.
Q: When should I use a horizontal autoclave instead of a vertical model?
A: Horizontal autoclaves are generally preferred when sterilizing larger batches or longer items, as their design facilitates easier loading and more even steam distribution. Their double-walled construction makes them suitable for laboratories with frequent and varied sterilization needs.
Q: Where should this autoclave be installed in a laboratory setting?
A: It should be placed on a stable, heat-resistant surface with nearby access to a 220V AC 50Hz single-phase power supply. Ensure sufficient ventilation and clearance for safe operation and easy maintenance.
Q: What is the process for operating the autoclave safely and efficiently?
A: Load the materials, ensure water is at the correct level, close the lid securely using wing nuts, set the desired pressure, and switch on the unit. Monitor the pressure gauge and release air or steam as needed. The spring-loaded safety valve enhances accuracy up to 3 psi for precise control.
Q: What benefits does the double-walled stainless steel construction provide?
A: Double-walled construction offers improved thermal retention and durability, reducing energy consumption and enhancing the autoclaves ability to withstand frequent use in a busy laboratory environment.
Q: How can regular maintenance prolong the life of the autoclave?
A: Routine cleaning, regular checks of the gasket and safety valve, monitoring the water level, and periodic inspection of the boiler and pressure gauge help maintain optimal performance and extend the equipments service life.