About Analgesiometer .
Analgesiometer
Specifications of Analgesiometer
Consisting of 30x30cms heating surface with perpex enclosure and solid state temperature controller with micro-controller based digital temperature indicator controller to set surface temp between 30ÂC to 80ÂC.
Versatile Applications in ResearchIdeal for pharmacological, veterinary, and broader biomedical research, this Analgesiometer is essential in quantifying pain response in laboratory animals. Its robust build and precise digital controls make it a trusted solution in both academic and industrial research settings.
User-Friendly Operation and SafetyDesigned for ease of use, the device offers manual and digital timer control, supported by overheat and fuse protections for added safety. Accessories such as an animal restrainer and comprehensive manual ensure streamlined workflow and minimal user training.
Certified Quality and Accurate MeasurementManufactured by an ISO 9001 certified provider, the Analgesiometer comes with a factory calibration certificate for dependable accuracy. Its digital display and least count capability allow for highly precise readings, critical for reproducible scientific studies.
FAQs of Analgesiometer:
Q: How is the Analgesiometer with Display used in laboratory research?
A: This instrument is primarily employed to measure pain sensitivity or response latency in laboratory animals, making it valuable in pharmacology, veterinary, and neurological studies. Researchers place the animal in the provided restrainer, set the desired parameters on the digital timer, and observe the reaction time when the heating element is applied.
Q: What is the process for calibrating and maintaining the device?
A: The Analgesiometer is supplied with a factory calibration certificate, ensuring accuracy out of the box. For ongoing maintenance, regular cleaning of the mild steel body and periodic checks of the heating element and fuse are recommended. Always follow the instruction manual for calibration and maintenance details.
Q: When should overheat and fuse protections be checked or reset?
A: The overheat and fuse protection mechanisms should be checked if the device does not reach the expected temperature or fails to operate. Always consult the instruction manual for reset and troubleshooting steps, and ensure the device is only used within the specified temperature (10C to 40C) and humidity range (up to 80% RH, non-condensing).
Q: Where can this Analgesiometer be installed for optimal performance?
A: For best results, install the device in a laboratory environment that maintains temperatures between 10C and 40C with humidity up to 80% RH (non-condensing). Adequate ventilation and easy access to a 220V AC, 50Hz power source are necessary for safe operation.
Q: What are the main benefits of the digital timer and display feature?
A: The digital timer and display ensure precise control and real-time monitoring of pain response measurements. With a wide timer range (0-99.9 s) and fine least count (0.1 s), researchers can record highly accurate and reproducible results.
Q: How does the single animal exposure design contribute to scientific accuracy?
A: Allowing exposure to only one animal at a time ensures controlled conditions and eliminates interference, thus providing more reliable and interpretable data for pain sensitivity studies.